1501:21-13-07. Freeboard requirements for dams
-
Sufficient freeboard shall be provided to prevent overtopping of the top of the dam due to passage of the design flood and other factors including, but not limited to, ice and wave action. The chief may approve a lower freeboard requirement if the dam is armored against overtopping erosion.
(A) For class I and class II dams that are upground reservoirs, the minimum elevation of the top of the dam shall be at least five feet higher than the elevation of the designed maximum operating pool level unless otherwise approved by the chief.
(B) For class III dams that are upground reservoirs, the minimum elevation of the top of the dam shall be at least three feet higher than the elevation of the designed maximum operating pool level unless otherwise approved by the chief.