3745-18-31. Franklin county emission limits  


Latest version.
  • (A) No owner or operator of a facility in Franklin county, unless otherwise specified in this rule, shall cause or permit the emission of sulfur dioxide from any stack in excess of the following rates:

    (1) For fossil fuel-fired steam generating units between 10.0 and 50.0 MM Btu per hour total rated heat input capacity, the emission rate in pounds of sulfur dioxide per MM Btu actual heat input shall be calculated by the following equation:

    EL = 8.088 Qm- 0.4307

    where:

    Qm is the total rated heat input capacity in MM Btu per hour, and EL is the allowable emission rate in pounds of sulfur dioxide per MM Btu actual heat input.

    (2) For fossil fuel-fired steam generating units equal to or greater than 50.0 MM Btu per hour total rated heat input capacity, the emission limitation shall be 1.50 pounds of sulfur dioxide per MM Btu actual heat input.

    (3) Except as otherwise provided in this rule, no owner or operator of any process equipment shall cause or permit the emission from any stack into the atmosphere of any process gas stream containing sulfur dioxide in excess of 2.40 pounds of sulfur dioxide per ton of actual process weight input.

    (B) The " Ohio ANG 121st Refueling Wing" (OEPA premise number 0125000827) or any subsequent owner or operator of the "Ohio ANG 121st Refueling Wing," Columbus, Ohio shall not cause or permit the emission of sulfur dioxide from any stack at this facility in excess of 2.20 pounds of sulfur dioxide per MM BTU actual heat input.

    (C) [Reserved.]

    (D) [Reserved.]

    (E) [Reserved.]

    (F) [Reserved.]

    (G) [Reserved.]

    (H) [Reserved.]

    (I) [Reserved.]

    (J) [Reserved.]

    (K) [Reserved.]

    (L) The "Ross Products - Division of Abbott" (OEPA premise number 0125040319) or any subsequent owner or operator of the "Ross Products - Division of Abbott, 625 Cleveland Avenue, Columbus, Ohio" shall not cause or permit the emission of sulfur dioxide from any stack at this facility in excess of 4.80 pounds of sulfur dioxide per MM Btu actual heat input.

    (M) [Reserved.]

    (N) The "Twin Valley Behavioral Healthcare" (OEPA premise number 0125040589) or any subsequent owner or operator of the "Twin Valley Behavioral Healthcare," Columbus, Ohio shall not cause or permit the emission of sulfur dioxide from any stack at this facility in excess of 4.10 pounds of sulfur dioxide per million BTU actual heat input.

    (O) [Reserved.]

    (P) [Reserved.]

    (Q) [Reserved.]

    (R) [Reserved.]

    (S) [Reserved.]

    (T) "Anheuser-Busch Columbus Brewery" (OEPA premise number 0125040554) or any subsequent owner or operator of "Anheuser-Busch Columbus Brewery, 700 Schrock Road, Columbus, Ohio" shall not cause or permit the emission of sulfur dioxide from boiler numbers 1 through 4 (OEPA source numbers B001 to B004) to exceed 2.4 pounds of sulfur dioxide per MM Btu actual heat input from each boiler and shall operate said boilers such that their combined average operating rate shall not exceed three hundred two MM Btu per hour for any calendar day.

Replaces: 3745-18-31


Effective: 2/16/2017
Five Year Review (FYR) Dates: 11/29/2021
Promulgated Under: 119.03
Statutory Authority: 3704.03(E)
Rule Amplifies: 3704.03(A), 3704.03(E)
Prior Effective Dates: 12/28/79, 5/11/87, 1/23/06, 2/17/11