4123:1-5-99 Table of standard materials and dimensions.
Where required by Chapter
4121:1-54123:1-5 of the Administrative Code, the following table to this rule shall be used.Table of standard materials and dimensions*
MaterialClearancefrom movingpart at allpointsLargestmesh ofopeningallowableMinimum gauge(U.S. Standard) orthicknessMinimumheight ofguard fromfloor orplatformlevelInchesInchesFeetWoven wireUnder 23/8No. 1672-41/2No. 167Under 41/2No. 1674-152No. 127Expanded metalUnder 41/2No. 1874-152No. 137Perforated metalUnder 41/2No. 2074-152No. 147Sheet metalUnder 4No. 2274-15No. 227Wood or metal stripcrossedUnder 43/8Wood 3/4 Metal No.1674-152Wood 3/4 Metal No.167Wood or metal stripnot crossedUnder 41/2 widthWood 3/4 Metal No.1674-151 widthWood 3/4 Metal No.167Standard guardrailing*Minimum 15Maximum 20*Guards constructed of these materials shall be securely fastened in place.**Permissible only where indicated.Distance of opening from hazard zone (inches)
0.5 to 1.5
0.25
Over 1.5 to 2.5
0.3725
Over 2.5 to 3.5
0.5
Over 3.5 to 5.5
0.625
Over 5.5 to 6.5
0.75
Over 6.5 to 7.5
0.875
Over 7.5 to 12.5
1.25
Over 12.5 to 15.5
1.5
Over 15.5 to 17.5
1.875
Over 17.5 to 31.5
2.125
Effective: 04/10/2011
R.C. 119.032 review dates: 03/03/2010 and 03/01/2016
CERTIFIED ELECTRONICALLY
Certification
03/10/2011
Date
Promulgated Under: 119.03
Statutory Authority: 4121.12, 4121.121, 4121.13
Rule Amplifies: 4121.47
Prior Effective Dates: 1/1/86
Document Information
- Effective Date:
- 4/10/2011
- File Date:
- 2011-03-10
- Last Day in Effect:
- 2011-04-10
- Five Year Review:
- Yes
- Rule File:
- 4123$1-5-99_PH_FF_A_RU_20110310_1209.pdf
- Related Chapter/Rule NO.: (1)
- Ill. Adm. Code 4123:1-5-99. Table of standard materials and dimensions