4101:3-2-01 Definitions.  

  • Text Box: ACTION: Final Text Box: DATE: 04/18/2011 11:49 AM

     

     

     

     

     

     

     

    4101:3-2-01   Definitions.

     

    [Comment: When a reference is made within this rule to a federal statutory provision, an industry consensus standard, or any other technical publication, the specific date and title of the publication as well as the name and address of the promulgating agency are listed in rule 4101:3-13-01 of the Administrative Code. The application of the referenced standards shall be limited and as prescribed in section 102.5 of rule 4101:1-1-01 of the Administrative Code.]

     

     

     

    SECTION 201 GENERAL

    201.1Scope. Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter.

    201.2Interchangeability. Words stated in the present tense include the future; words stated in the masculine gender include the feminine and neuter; the singular number includes the plural and the plural the singular.

    201.3Terms defined in other codes. Where terms are not defined in this code and are defined in the building code, fire code, "International Fuel Gas Code" or the mechanical code, such terms shall have the meanings ascribed to them as in those codes.

    201.4Terms not defined. Where terms are not defined through the methods authorized by this section, such terms shall have ordinarily accepted meanings such as the context implies.

     

     

    SECTION 202 GENERAL DEFINITIONS

     

    ACCEPTED ENGINEERING PRACTICE. That which conforms to accepted principles, tests  or standards of nationally recognized technical or scientific authorities. Where a standard is  referred to in Chapter 4101:3-13 of the Administrative Code relative to "accepted engineering  practice," conformity to the applicable technical provisions, requirements, recommendations,  and determinations in the standard or other publications is prima-fascia evidence of conformity  with accepted engineering practice.

     

    ACCESS (TO). That which enables a fixture, appliance or equipment to be reached by ready access or by a means that first requires the removal or movement of a panel, door or similar obstruction (see "Ready access").

    ACCESS COVER. A removable plate, usually secured by bolts or screws, to permit access to a pipe or pipe fitting for the purposes of inspection, repair or cleaning.

    ADAPTER FITTING. An  approved  connecting  device  that suitably  and  properly  joins  or adjusts pipes and fittings which do not otherwise fit together.

    AIR ADMITTANCE VALVE. One-way valve designed to allow air to enter the plumbing drainage system when negative pressures develop in the piping system. The device shall close by

     

     

    gravity and seal the vent terminal at zero differential pressure (no flow conditions) and under positive internal pressures. The purpose of an air admittance valve is to provide a method of allowing air to enter the plumbing drainage system without the use of a vent extended to open air and to prevent sewer gases from escaping into a building.

    AIR BREAK (Drainage System). A piping arrangement in which a drain from a fixture, appliance or device discharges indirectly into another fixture, receptacle or interceptor at a point below the flood level rim and above the trap seal.

    AIR GAP (Drainage System). The unobstructed vertical distance through the free atmosphere between the outlet of the waste pipe and the flood level rim of the receptacle into which the waste pipe is discharging.

    AIR GAP (Water Distribution System). The unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture or other device and the flood level rim of the receptacle.

    ALTERNATIVE ENGINEERED DESIGN. A plumbing system that performs in accordance  with the intent of Chapters 3 through 12 and provides an equivalent level of performance for the protection of public health, safety and welfare. The system design is not specifically regulated by Chapters 3 through 12 in accordance with the requirements of section 106 of the building code.  ANCHORS. See "Supports."

    ANTISIPHON. A term applied to valves or mechanical devices that eliminate siphonage.

    APPROVED. Determined to be in compliance by the authority having jurisdiction in  accordance with the rules of the board.

    APPROVED AGENCY. An established and recognized agency that is regularly engaged in conducting tests and/or inspection services, when such agency has been approved in accordance with the rules of the board and published in Appendix O.

    AREA DRAIN. A receptacle designed to collect surface or storm water from an open area.

    ASPIRATOR. A fitting or device supplied with water or other fluid under positive pressure that passes through an integral orifice or constriction, causing a vacuum. Aspirators are also referred to as suction apparatus, and are similar in operation to an ejector.

    BACKFLOW. Pressure created by any means in the water distribution system, which by being in excess of the pressure in the water supply mains causes a potential backflow condition.

    Backpressure, low head. A pressure less than or equal to 4.33 psi (29.88 kPa) or the pressure exerted by a 10-foot (3048 mm) column of water.

    Backsiphonage. The backflow of potentially contaminated water into the potable  water system as a result of the pressure in the potable water system falling below atmospheric pressure of the plumbing fixtures, pools, tanks or vats connected to the potable water distribution piping.

    Drainage. A reversal of flow in the drainage system.

    Water supply system. The flow of water or other liquids, mixtures or substances into the distribution pipes of a potable water supply from any source except the intended source.

    BACKFLOW CONNECTION. Any arrangement whereby backflow is possible.

    BACKFLOW PREVENTER. A device or means to prevent backflow.

    BACKWATER VALVE. A device or valve installed in the building drain or sewer pipe where a sewer is subject to backflow, and which prevents drainage or waste from backing up into a lower level or fixtures and causing a flooding condition.

    BASE FLOOD ELEVATION. A reference point, determined in accordance with the building code, based on the depth or peak elevation of flooding, including wave height, which has a 1 percent (100-year flood) or greater chance of occurring in any given year.

    BATHROOM GROUP. A group of fixtures consisting of a water closet, lavatory, bathtub or shower, including or excluding a bidet, an emergency floor drain or both. Such fixtures are located together on the same floor level.

    BEDPAN STEAMER OR BOILER. A fixture utilized for scalding bedpans or urinals by direct application of steam or boiling water.

    BEDPAN WASHER AND STERILIZER. A fixture designed to wash bedpans and to flush the contents into the sanitary drainage system. Included are fixtures of this type that provide for disinfecting utensils by scalding with steam or hot water.

    BEDPAN WASHER HOSE. A device supplied with hot and cold water and located adjacent to a water closet or clinical sink to be utilized for cleansing bedpans.

    BRANCH. Any part of the piping system except a riser, main or stack.

    BRANCH INTERVAL. A vertical measurement of distance, 8 feet (2438 mm) or more in developed length, between the connections of horizontal branches to a drainage stack. Measurements are taken down the stack from the highest horizontal branch connection.

    BRANCH VENT. A vent connecting one or more individual vents with a vent stack or stack vent.

    BUILDING. Any structure consisting of foundations, walls, columns, girders, beams, floors,  and roof, or a combination of any number of these parts, with or without other parts or  appurtenances. See division (C)(2) of section 3781.06 of the Revised Code.

    BUILDING CODE. The "Ohio Building Code".

    BUILDING DRAIN. That part of the lowest piping of a drainage system that receives the discharge from soil, waste and other drainage pipes inside and that extends 30 inches (762 mm) in developed length of pipe beyond the exterior walls of the building and conveys the drainage to the building sewer.

    Combined. A building drain that conveys both sewage and storm water or other drainage.   Sanitary. A building drain that conveys sewage only.

    Storm. A building drain that conveys storm water or other drainage, but not sewage.

    BUILDING OFFICIAL. See definition of "Building Official" in rule 4101:1-2-01 of the  Administrative Code.  

    BUILDING SERVICES PIPING. All piping systems and their component parts that are part of a building system and that promote the safe, sanitary, and energy efficient occupancy of a building.  Building services piping  includes, but is not limited to, cold and hot potable water

    distribution for plumbing fixtures; sanitary lines from plumbing fixtures; nonflammable medical gas systems; medical oxygen systems; medical vacuum systems; fire protection piping systems and compressed air in dry systems; refrigeration, chilled water, condenser and cooling tower water, brine, and water/antifreeze systems; steam, steam condensate, and hot water piping systems; and fuel oil piping and fuel gas piping for heating, cooling, and cooking applications. See division (A) of section 4104.41 of the Revised Code.

    BUILDING SEWER. That part of the drainage system that extends from the end of the building drain and conveys the discharge to a public sewer, private sewer, individual sewage disposal system or other point of disposal.

    Combined. A building sewer that conveys both sewage and storm water or other drainage.   Sanitary. A building sewer that conveys sewage only.

    Storm. A building sewer that conveys storm water or other drainage, but not sewage.

    BUILDING SUBDRAIN. That portion of a drainage system that does not drain by gravity into the building sewer.

    BUILDING TRAP. A device, fitting or assembly of fittings installed in the building drain to prevent circulation of air between the drainage system of the building and the building sewer.

    CIRCUIT VENT. A vent that connects to a horizontal drainage branch and vents two traps to a maximum of eight traps or trapped fixtures connected into a battery.

    CISTERN. A small covered tank for storing water for a home or farm. Generally, this tank stores rainwater to be utilized for purposes other than in the potable water supply, and such tank is placed underground in most cases.

    CLEANOUT. An access opening in the drainage system utilized for the removal of obstructions. Types of cleanouts include a removable plug or cap, and a removable fixture or fixture trap.

    CODE. Those rules contained in division number 4101:3 of the Administrative Code.

    CODE OFFICIAL. See definition of "Building official" in rule 4101:1-2-01 of the  Administrative Code.

    COMBINATION FIXTURE. A fixture combining one sink and laundry tray or a two-or three- compartment sink or laundry tray in one unit.

    COMBINATION WASTE AND VENT SYSTEM. A specially designed system of waste piping embodying the horizontal wet venting of one or more sinks or floor drains by means of a common waste and vent pipe adequately sized to provide free movement of air above the flow line of the drain.

    COMBINED BUILDING DRAIN. See "Building drain, combined."   COMBINED BUILDING SEWER. See "Building sewer, combined."

    COMMON VENT. A vent connecting at the junction of two fixture drains or to a fixture branch and serving as a vent for both fixtures.

    CONCEALED FOULING SURFACE. Any surface of a plumbing fixture which is not readily

    visible and is not scoured or cleansed with each fixture operation.

    CONDUCTOR. A pipe inside the building that conveys storm water from the roof to a storm or combined building drain.

    CONSTRUCTION DOCUMENTS. All of the written, graphic and pictorial documents prepared or assembled for describing the design, location and physical characteristics of the  elements of the project necessary for obtaining plan approval in accordance with section 106 of  rule 4101:1-1-01 of the Administrative code.                                        

    CONTAMINATION. An impairment of the quality of the potable water that creates an actual hazard to the public health through poisoning or through the spread of disease by sewage, industrial fluids or waste.

    CRITICAL LEVEL (C-L). An elevation (height) reference point that determines the minimum height at which a backflow preventer or vacuum breaker is installed above the flood level rim of the fixture or receptor served by the device. The critical level is the elevation level below which there is a potential for backflow to occur. If the critical level marking is not indicated on the device, the bottom of the device shall constitute the critical level.

    CROSS CONNECTION. Any physical connection or arrangement between two otherwise separate piping systems, one of which contains potable water and the other either water of unknown or questionable safety or steam, gas or chemical, whereby there exists the possibility for flow from one system to the other, with the direction of flow depending on the pressure differential between the two systems (see "Backflow").

    DEAD END. A branch leading from a soil, waste or vent pipe; a building drain;or a building sewer, and terminating at a developed length of 2 feet (610 mm) or more by means of a plug, cap or other closed fitting.

    DEPTH OF TRAP SEAL. The depth of liquid that would have to be removed from a full trap  before air could pass through the trap.            

    DESIGN FLOOD ELEVATION. The elevation of the "design flood," including wave height, relative to the datum specified on the legally designated flood hazard map.

    DEVELOPED LENGTH. The length of a pipeline measured along the centerline of the pipe and fittings.

    DISCHARGE PIPE. A pipe that conveys the discharges from plumbing fixtures or appliances.

    DRAIN. Any pipe that carries wastewater or water-borne wastes in a building drainage system.

    DRAINAGE FITTINGS. Type of fitting or fittings utilized in the drainage system. Drainage fittings are similar to cast-iron fittings, except that instead of having a bell and spigot, drainage fittings are recessed and tapped to eliminate ridges on the inside of the installed pipe.

    DRAINAGE FIXTURE UNIT

    Drainage (dfu). A measure of the probable discharge into the drainage system by various types of plumbing fixtures. The drainage fixture-unit value for a particular fixture depends on its volume rate of drainage discharge, on the time duration of a single drainage operation and on the average time between successive operations.

    DRAINAGE  SYSTEM.  Piping  within  a  public  or  private  premise  that  conveys  sewage,

    rainwater or other liquid wastes to a point of disposal. A drainage system does not include the mains of a public sewer system or a private or public sewage treatment or disposal plant.

    Building gravity. A drainage system that drains by gravity into the building sewer.

    Sanitary. A drainage system that carries sewage and excludes storm, surface and ground water.

    Storm. A drainage system that carries rainwater, surface water, subsurface water and similar liquid wastes.

    EFFECTIVE OPENING. The minimum cross-sectional area at the point of water supply discharge, measured or expressed in terms of the diameter of a circle or, if the opening is not circular, the diameter of a circle of equivalent cross-sectional area. For faucets and similar fittings, the effective opening shall be measured at the smallest orifice in the fitting body or in the supply piping to the fitting.

    EMERGENCY FLOOR DRAIN. A floor drain that does not receive the discharge of any drain or indirect waste pipe, and that protects against damage from accidental spills, fixture overflows and leakage.

    ESSENTIALLY NONTOXIC TRANSFER FLUIDS. Fluids having a Gosselin rating of 1, including propylene glycol; mineral oil; polydimethylsiloxane; hydrochlorofluorocarbon, chlorofluorocarbon and carbon refrigerants; and FDA-approved boiler water additives for steam boilers.

    ESSENTIALLY TOXIC TRANSFER FLUIDS. Soil, waste or gray water and fluids having a Gosselin rating of 2 or more including ethylene glycol, hydrocarbon oils, ammonia refrigerants and hydrazine.

    EXISTING INSTALLATIONS. Any plumbing system regulated by this code that was  installed, or for which an approval has been issued.

    FAUCET. A valve end of a water pipe through which water is drawn from or held within the pipe.

    FILL VALVE. A water supply valve, opened or closed by means of a float or similar device, utilized to supply water to a tank. An antisiphon fill valve contains an antisiphon device in the form of an approved air gap or vacuum breaker that is an integral part of the fill valve unit and that is positioned on the discharge side of the water supply control valve.

    FIRE  CODE. The "Ohio Fire Code".

    FIXTURE. See "Plumbing fixture."

    FIXTURE BRANCH. A drain serving two or more fixtures that discharges to another drain or to a stack.

    FIXTURE DRAIN. The drain from the trap of a fixture to a junction with any other drain pipe.   FIXTURE FITTING

    Supply fitting. A fitting that controls the volume and/or directional flow of water and is either attached to or accessible from a fixture, or is used with an open or atmospheric discharge.

    Waste fitting. A combination of components that conveys the sanitary waste from the outlet of a fixture to the connection to the sanitary drainage system.

    FIXTURE SUPPLY. The water supply pipe connecting a fixture to a branch water supply pipe

    or directly to a main water supply pipe.

    FLOOD HAZARD AREA. The greater of the following two areas:

    1.The area within a flood plain subject to a 1-percent or greater chance of flooding in any given year.

    2.The area designated as a flood hazard area on a legally designated flood hazard map.

    FLOOD LEVEL RIM. The edge of the receptacle from which water overflows.

    FLOW CONTROL (Vented). A device installed upstream from the interceptor having an orifice that controls the rate of flow through the interceptor and an air intake (vent) downstream from the orifice that allows air to be drawn into the flow stream.

    FLOW PRESSURE. The pressure in the water supply pipe near the faucet or water outlet while the faucet or water outlet is wide open and flowing.

    FLUSH TANK. A tank designed with a fill valve and flush valve to flush the contents of the bowl or usable portion of the fixture.

    FLUSHOMETER TANK. A device integrated within an air accumulator vessel that is designed to discharge a predetermined quantity of water to fixtures for flushing purposes.

    FLUSHOMETER VALVE. A valve attached to a pressurized water supply pipe and so designed that when activated it opens the line for direct flow into the fixture at a rate and quantity to operate the fixture properly, and then gradually closes to reseal fixture traps and avoid water hammer.

    GRAY WATER. Waste discharged from lavatories, bathtubs, showers, clothes washers and  laundry trays.

    GREASE INTERCEPTOR. A plumbing appurtenance that is installed in a sanitary drainage system to intercept oily and greasy wastes from a wastewater discharge. Such device has the ability to intercept free-floating fats and oils.

    GREASE-LADEN WASTE. Effluent discharge that is produced from food processing, food preparation or other sources where grease, fats and oils enter automatic dishwater prerinse stations, sinks or other appurtenances.

    GREASE REMOVAL DEVICE, AUTOMATIC (GRD). A plumbing appurtenance that is installed in the sanitary drainage system to intercept free-floating fats, oils and grease from wastewater discharge. Such a device operates on a time-or event-controlled basis and has the ability to remove free-floating fats, oils and grease automatically without intervention from the user except for maintenance.

    GRIDDED WATER DISTRIBUTION SYSTEM. A water distribution system where every water distribution pipe is interconnected so as to provide two or more paths to each fixture supply pipe.

    HANGERS. See "Supports."

    HORIZONTAL BRANCH DRAIN. A drainage branch pipe extending laterally from a soil or waste stack or building drain, with or without vertical sections or branches, that receives the discharge from two or more fixture drains or branches and conducts the discharge to the soil or waste stack or to the building drain.

    HORIZONTAL PIPE. Any pipe or fitting that makes an angle of less than 45 degrees (0.79 rad) with the horizontal.

    HOT WATER. Water at a temperature greater than or equal to 110°F (43°C).   HOUSE TRAP. See "Building trap."

    HUB DRAIN. A drain whose inlet terminates not less than one inch (25.4mm) above the finished floor.

    INDIRECT WASTE PIPE. A waste pipe that does not connect directly with the drainage system, but that discharges into the drainage system through an air break or air gap into a trap, fixture, receptor or interceptor.

    INDIVIDUAL SEWAGE DISPOSAL SYSTEM. A system for disposal of domestic sewage by means of a septic tank, cesspool or mechanical treatment, designed for utilization apart from a public sewer to serve a single establishment or building.

    INDIVIDUAL VENT. A pipe installed to vent a fixture trap and that connects with the vent system above the fixture served or terminates in the open air.

    INDIVIDUAL WATER SUPPLY. A water supply that serves one or more families, and that is not an approved public water supply.

    INTERCEPTOR. A device designed and installed to separate and retain for removal, by automatic or manual means, deleterious, hazardous or undesirable matter from normal wastes, while permitting normal sewage or wastes to discharge into the drainage system by gravity.

    JOINT

    Expansion. A loop, return bend or return offset that provides for the expansion and contraction in a piping system and is utilized in tall buildings or where there is a rapid change of temperature, as in power plants, steam rooms and similar occupancies.

    Flexible. Any joint between two pipes that permits one pipe to be deflected or moved without movement or deflection of the other pipe.

    Mechanical. See "Mechanical joint."

    Slip. A type of joint made by means of a washer or a special type of packing compound in which one pipe is slipped into the end of an adjacent pipe.

    JURISDICTION. The authority to enforce this code by municipal corporations, townships or counties certified by the board in accordance with section 3781.10 of the Revised Code, or by general health districts, or by the division of industrial compliance in the department of commerce.

    LABEL. An identification applied on a product by the manufacturer that contains the name of  the manufacturer, the function and performance characteristics of the product or material, and the name and identification of an approved agency and that indicates that the representative  sample of the product or material has been tested and evaluated by an approved agency (see  building code section 1703.5 and building code definitions "Inspection Certificate,"  "Manufacturer's Designation," and "Mark").

    LEAD-FREE PIPE AND FITTINGS. Containing not more than 8.0-percent lead.   LEAD-FREE SOLDER AND FLUX. Containing not more than 0.2-percent lead.

    LEADER. An exterior drainage pipe for conveying storm water from roof or gutter drains to an approved means of disposal.

    LISTED. Equipment, appliances or materials included in a directory published by an approved agency whose listing states either that equipment, appliances or materials meet standards listed in this code or have been tested and found suitable for use in a specified manner.

    LOCAL VENT STACK. A vertical pipe to which connections are made from the fixture side of traps and through which vapor or foul air is removed from the fixture or device utilized on bed- pan washers.

    MACERATING TOILET SYSTEMS. An assembly consisting of a water closet and sump with a macerating pump that is designed to collect, grind and pump wastes from the water closet and up to two other fixtures connected to the sump.

    MAIN. The principal pipe artery to which branches are connected.   MANIFOLD. See "Plumbing appurtenance."

    MECHANICAL CODE. The "Ohio Mechanical Code".

    MECHANICAL JOINT. A connection between pipes, fittings, or pipes and fittings that is not screwed, caulked, threaded, soldered, solvent cemented, brazed or welded. A joint in which compression is applied along the centerline of the pieces being joined. In some applications, the joint is part of a coupling, fitting or adapter.

    MEDICAL GAS SYSTEM. The complete system to convey medical gases for direct patient application from central supply systems (bulk tanks, manifolds and medical air compressors), with pressure and operating controls, alarm warning systems, related components and piping networks extending to station outlet valves at patient use points.

    MEDICAL VACUUM SYSTEMS. A system consisting of central-vacuum-producing equipment with pressure and operating controls, shutoff valves, alarm-warning systems, gauges and a network of piping extending to and terminating with suitable station inlets at locations where patient suction may be required.

    NONPOTABLE WATER. Water not safe for drinking, personal or culinary utilization.   NUISANCE. See "Public Nuisance."

    OCCUPANCY. The purpose for which a building or portion thereof is utilized or occupied.

    OFFSET. A combination of approved bends that makes two changes in direction bringing one section of the pipe out of line but into a line parallel with the other section.

    OPEN AIR. Outside the structure.

    PLUMBING. The practice, materials and fixtures utilized in the installation, maintenance, extension and alteration of all piping, fixtures, plumbing appliances and plumbing appurte- nances, within or adjacent to any structure, in connection with sanitary drainage or  storm drainage facilities; venting systems; and public or private water supply systems.

    PLUMBING APPLIANCE. Any one of a special class of plumbing fixtures intended to perform a special function. Included are fixtures having the operation or control dependent on one or more energized components, such as motors, controls, heating elements, or pressure-or temperature-sensing elements.

    Such fixtures are manually adjusted or controlled by the owner or operator, or are operated automatically through one or more of the following actions: a time cycle, a temperature range, a pressure range, a measured volume or weight.

    PLUMBING APPURTENANCE. A manufactured device, prefabricated assembly or an on- the-job assembly of component parts that is an adjunct to the basic piping system and plumbing fixtures. An appurtenance demands no additional water supply and does not add any discharge load to a fixture or to the drainage system.

    PLUMBING FIXTURE. A receptacle or device that is either permanently or temporarily connected to the water distribution system of the premises and demands a supply of water there- from; discharges wastewater, liquid-borne waste materials or sewage either directly or indirectly to the drainage system of the premises; or requires both a water supply connection and a discharge to the drainage system of the premises.

    PLUMBING SYSTEM. Includes the water supply and distribution pipes; plumbing fixtures and traps; water-treating or water-using equipment; soil, waste and vent pipes; and sanitary and storm sewers and building drains; in addition to their respective connections, devices and appurtenances within a structure or premises.

    POLLUTION. An impairment of the quality of the potable water to a degree that does not create a hazard to the public health but that does adversely and unreasonably affect the aesthetic qualities of such potable water for domestic use.

    POTABLE WATER. Water free from impurities present in amounts sufficient to cause disease or harmful physiological effects and conforming to the bacteriological and chemical quality requirements of the Public Health Service Drinking Water Standards or the regulations of the public health authority having jurisdiction.

    POWER PIPING.  Piping systems and their component parts that are not building services  piping systems, and that may be installed within electric power generating stations, industrial and institutional plants, utility geothermal heating systems, and central and district heating and  cooling systems.  Power piping includes, but is not limited to, piping used in the distribution of  plant and process steam at boiler pressures greater than fifteen pounds per square inch gauge,  high temperature water piping from high pressure and high temperature boilers, power boiler  steam condensate piping, high pressure and high temperature water condensate piping, and  compressed air and hydraulic piping upstream of the first stop valve off a system distribution header. See division (B) of section 4104.41 of the Revised Code.

    PRIVATE. In the classification of plumbing fixtures, "private" applies to fixtures in residences and apartments, and to fixtures in nonpublic toilet rooms of hotels and motels and similar installations in buildings where the plumbing fixtures are intended for utilization by a family or an individual.

    PROCESS PIPING. Piping systems and their component parts that are not building services or power piping systems and that may be installed in petroleum refineries; chemical,

    pharmaceutical, textile, paper, semiconductor, and cryogenic plants; and related processing  plants and terminals. See division (C) of section 4104.41 of the Revised Code.

    PUBLIC NUISANCE.  Any building, structure, or part thereof, constructed, erected, altered,  manufactured, or repaired not in accordance with the Ohio Revised Code or the rules of the  board, and any building, structure, or part thereof in which there is installed, altered, or  repaired any fixture, device, and material, or plumbing, heating, or ventilating system, or  electric wiring not in accordance with the Ohio Revised Code or the rules of the board. See  division (C) of section 3781.11 of the Revised Code.

    PUBLIC OR PUBLIC UTILIZATION. In the classification of plumbing fixtures, "public" applies to fixtures in general toilet rooms of schools, gymnasiums, hotels, airports, bus and  railroad stations, public buildings, bars, public comfort stations, office buildings, stadiums,  stores, restaurants and other installations where toilet fixtures are intended for public use.

    PUBLIC WATER MAIN. A water supply pipe for public utilization controlled by public authority.

    QUICK-CLOSING VALVE. A valve or faucet that closes automatically when released manually or that is controlled by a mechanical means for fast-action closing.

    READY ACCESS. That which enables a fixture, appliance or equipment to be directly reached  without requiring the removal or movement of any panel, door or similar obstruction and without the use of a portable ladder, step stool or similar device. (See "Access (to)")

    REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER. A backflow prevention device consisting of two independently acting check valves, internally force-loaded to a normally closed position and separated by an intermediate chamber (or zone) in which there is an automatic relief means of venting to the atmosphere, internally loaded to a normally open position between two tightly closing shutoff valves and with a means for testing for tightness of the checks and opening of the relief means.

    REGISTERED DESIGN PROFESSIONAL. Any person holding a certificate issued under  sections 4703.10, 4703.36 or 4733.14 of the Revised Code.

    RELIEF VALVE

    Pressure relief valve. A pressure-actuated valve held closed by a spring or other means and designed to relieve pressure automatically at the pressure at which such valve is set.

    Temperature and pressure relief (T&P) valve. A combination relief valve designed to function as both a temperature relief and a pressure relief valve.

    Temperature relief valve. A temperature-actuated valve designed to discharge automatically at the temperature at which such valve is set.

    RELIEF  VENT.  A  vent  whose  primary  function  is  to  provide  circulation  of  air  between drainage and vent systems.

    RIM. An unobstructed open edge of a fixture.

    RISER. See "Water pipe, riser."

    RODENT PROOFING. The installation of plumbing systems in a manner which will prevent the entry of rodents into a structure through openings created when any part of a plumbing system  penetrates an exterior wall or floor assembly located near or on grade.

    ROOF DRAIN. A drain installed to receive water collecting on the surface of a roof and to discharge such water into a leader or a conductor.

    ROUGH-IN. Parts of the plumbing system that are installed prior to the installation of fixtures. This includes drainage, water supply, vent piping and the necessary fixture supports and any fixtures that are built into the structure.

    SELF-CLOSING FAUCET. A faucet containing a valve that automatically closes upon deactivation of the opening means.

    SEPARATOR. See "Interceptor."

    SEWAGE. Any liquid waste containing animal or vegetable matter in suspension or solution, including liquids containing chemicals in solution.

    SEWAGE EJECTORS. A device for lifting sewage by entraining the sewage in a high-velocity jet of steam, air or water.

    SEWER

    Building sewer. See "Building sewer."

    Public sewer. A common sewer directly controlled by public authority.

    Sanitary sewer. A sewer that carries sewage and excludes storm, surface and ground water.

    Storm sewer. A sewer that conveys rainwater, surface water, subsurface water and similar liquid wastes.

    SINK, SERVICE. Any designated sink so approved for liquid discharge, liquid filling, cleaning, and washing in a facility, and installed in a dedicated area or space.

    SLOPE. The fall (pitch) of a line of pipe in reference to a horizontal plane. In drainage, the slope is expressed as the fall in units vertical per units horizontal (percent) for a length of pipe.

    SOIL PIPE. A pipe that conveys sewage containing fecal matter to the building drain or building sewer.

    SPILLPROOF VACUUM BREAKER. An assembly consisting of one check valve force- loaded closed and an air-inlet vent valve force-loaded open to atmosphere, positioned down- stream of the check valve, and located between and including two tightly closing shutoff valves and a test cock.

    STACK. A general term for any vertical line of soil, waste, vent or inside conductor piping that extends through at least one story with or without offsets.

    STACK VENT. The extension of a soil or waste stack above the highest horizontal drain connected to the stack.

    STACK VENTING. A method of venting a fixture or fixtures through the soil or waste stack.   STERILIZER

    Boiling type. A boiling-type sterilizer is a fixture of a nonpressure type utilized for boiling instruments, utensils or other equipment for disinfection. These devices are portable or are connected to the plumbing system.

    Instrument. A device for the sterilization of various instruments.

    Pressure (autoclave). A pressure vessel fixture designed to utilize steam under pressure for sterilizing.

    Pressure instrument washer sterilizer. A pressure instrument washer sterilizer is a pressure vessel fixture designed to both wash and sterilize instruments during the operating cycle of the fixture.

    Utensil. A device for the sterilization of utensils as utilized in health care services.   Water. A water sterilizer is a device for sterilizing water and storing sterile water.

    STERILIZER VENT. A separate pipe or stack, indirectly connected to the building drainage system at the lower terminal, that receives the vapors from nonpressure sterilizers, or the exhaust vapors from pressure sterilizers, and conducts the vapors directly to the open air. Also called vapor, steam, atmospheric or exhaust vent.

    STORM DRAIN. See "Drainage system, storm."

    STRUCTURE. That which is built or constructed or a portion thereof.

    SUBSOIL DRAIN. A drain that collects subsurface water or seepage water and conveys such water to a place of disposal.

    SUMP. A tank or pit that receives sewage or liquid waste, located below the normal grade of the gravity system and that must be emptied by mechanical means.

    SUMP PUMP. An automatic water pump powered by an electric motor for the removal of drainage, except raw sewage, from a sump, pit or low point.

    SUMP VENT. A vent from pneumatic sewage ejectors, or similar equipment, that terminates separately to the open air.

    SUPPORTS. Devices for supporting and securing pipe, fixtures and equipment.

    SWIMMING POOL. See section 3109.2 of the building code for classifications of swimming  pool.

    TEMPERED WATER. Water having a temperature range between 85°F (29°C) and 110°F (43°C).

    THIRD-PARTY CERTIFICATION AGENCY. See "APPROVED AGENCY".  THIRD-PARTY CERTIFIED.  See "LISTED".

    THIRD-PARTY TESTED. Procedure by which an approved agency provides documentation that a product, material or system conforms to specified requirements.

    TRAP. A fitting or device that provides a liquid seal to prevent the emission of sewer gases without materially affecting the flow of sewage or wastewater through the trap.

    TRAP SEAL. The vertical distance between the weir and the top of the dip of the trap.

    UNSTABLE GROUND. Earth that does not provide a uniform bearing for the barrel of the sewer pipe between the joints at the bottom of the pipe trench.

    VACUUM. Any pressure less than that exerted by the atmosphere.

    VACUUM BREAKER. A type of backflow preventer installed on openings subject to normal atmospheric pressure that prevents backflow by admitting atmospheric pressure through ports to the discharge side of the device.

    VENT PIPE. See "Vent system."

    VENT STACK. A vertical vent pipe installed primarily for the purpose of providing circulation of air to and from any part of the drainage system.

    VENT SYSTEM. A pipe or pipes installed to provide a flow of air to or from a drainage system, or to provide a circulation of air within such system to protect trap seals from siphonage and backpressure.

    VERTICAL PIPE. Any pipe or fitting that makes an angle of 45 degrees (0.79 rad) or more with the horizontal.

    WALL-HUNG WATER CLOSET. A wall-mounted water closet installed in such a way that the fixture does not touch the floor.

    WASTE. The discharge from any fixture, appliance, area or appurtenance that does not contain fecal matter.

    WASTE PIPE. A pipe that conveys only waste.

    WASTE RECEPTOR. A device for receiving the discharge of a waste pipe or pipes and  discharges them by gravity into the sanitary drainage system. Waste receptors include, but are  not limited to, floor drains, floor sinks, trench drains, hub drains, standpipes, mop basins,  service sinks, and laundry trays.

    WATER-HAMMER ARRESTOR. A device utilized to absorb the pressure surge (water hammer) that occurs when water flow is suddenly stopped in a water supply system.

    WATER HEATER. Any heating appliance or equipment that heats potable water and supplies such water to the potable hot water distribution system.

    WATER MAIN. A water supply pipe or system of pipes, installed and maintained by a city, township, county, public utility company or other public entity, on public property, in the street or in an approved dedicated easement of public or community use.

    WATER OUTLET. A discharge opening through which water is supplied to a fixture, into the atmosphere (except into an open tank that is part of the water supply system), to a boiler or heating system, or to any devices or equipment requiring water to operate but which are not part of the plumbing system.

    WATER PIPE

    Riser. A water supply pipe that extends one full story or more to convey water to branches or to a group of fixtures.

    Water distribution pipe. A pipe within the structure or on the premises that conveys water from the water service pipe, or from the meter when the meter is at the structure, to the points of utilization.

    Water service pipe. The pipe from the water main or other source of potable water supply, or from the meter when the meter is at the public right of way, to the water distribution system of the building served.

    WATER SUPPLY SYSTEM. The water service pipe, water distribution pipes, and the necessary connecting pipes, fittings, control valves and all appurtenances in or adjacent to the structure or premises.

    WELL

    Bored. A well constructed by boring a hole in the ground with an auger and installing a casing.

    Drilled. A well constructed by making a hole in the ground with a drilling machine of any type and installing casing and screen.

    Driven. A well constructed by driving a pipe in the ground. The drive pipe is usually fitted with a well point and screen.

    Dug. A well constructed by excavating a large-diameter shaft and installing a casing.

    WHIRLPOOL BATHTUB. A plumbing appliance consisting of a bathtub fixture that is equipped and fitted with a circulating piping system designed to accept, circulate and discharge bathtub water upon each use.

    YOKE VENT. A pipe connecting upward from a soil or waste stack to a vent stack for the purpose of preventing pressure changes in the stacks.

    4101:3-2-01                                                                                                                         16

    Replaces:                                                     4101:3-2-01

    Effective:                                                     11/01/2011

    R.C. 119.032 review dates:                         11/01/2016

    CERTIFIED ELECTRONICALLY

    Certification

    04/18/2011

    Date

    Promulgated Under:                           119.03

    Statutory Authority:                           3781.10(A)

    Rule Amplifies:                                  3781.10, 3781.11, 3791.04, 4104.41

    Prior Effective Dates:                         7/1/95, 3/1/98, 4/1/99, 1/1/02, 3/1/05, 7/1/07

Document Information

Effective Date:
11/1/2011
File Date:
2011-04-18
Last Day in Effect:
2011-11-01
Rule File:
4101$3-2-01_PH_FF_N_RU_20110418_1149.pdf
Related Chapter/Rule NO.: (1)
Ill. Adm. Code 4101:3-2-01. Definitions